|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DB LECTRO Inc. N 17.5x6.5x12.5 Features G 6 D Small size, light weight. Low coil power consumption 0.2W. PC board mounting. Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities. Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance & Voltage drop Operation Electrical life Mechanical 1A Silver Alloy 5A/30VDC,250VAC ; 150W 1250VA 30VDC 250VAC 100m 1y105 2y107 min Load:10mA/5VDC Max. Switching Current:5A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 CAUTION: Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications. Coil Parameter Coil voltage VDC Pickup voltage VDC(max) (75%of rated voltage ) release voltage VDC(min) (10% of rated voltage) Coil power consumption W Operate Time ms Release Time ms Coil resistance 10% Rated 5 12 24 Max. 6.5 125 3.75 0.5 10 5 0.2W 15.6 720 9.00 1.2 31.2 2880 18.0 2.4 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 and 8 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 750V 50Hz 3000V Surge voltage:6kV Functional 100m/s2 11ms Endurance 1000m/s2 6ms 10~55Hz Functional double amplitude 1.5mm Endurance double amplitude 1.5mm 5N 230x2 10x0.5s -25~70 35%~85% 3g Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. 49 NG6D Ordering Information NG6D A DC12V Coil rated DC Voltage 5V, 12V24V Contact ArrangementA1A Part numberNG6D Dimensions (Unit: mm) 2,54 0.1 0.043 Mounting (Bottom views) Dimensions Wiring diagram (Bottom views) mm 0.3 0.6 0.8 1.1 1.13 2.54 3.5 5.08 6.5 7.62 12.5 15.24 17.5 inch 0.012 0.020 0.031 0.043 0.044 0.100 0.138 0.200 0.244 0.300 0.492 0.600 0.689 2,54 NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. DB LECTRO Inc. 0.1 |
Price & Availability of NG6DADC12V |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |